Acta Radiol ; 64(5): 1799-1807, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36437753

RESUMO

BACKGROUND: Previous studies have shown differences in technical image quality between digital breast tomosynthesis (DBT) systems. However, quantitative image quality measurements may not necessarily fully reflect the clinical performance of DBT. PURPOSE: To study the subjective image quality of five DBT systems manufactured by Fujifilm, GE, Hologic, Planmed, and Siemens using phantom images. MATERIAL AND METHODS: A TOR MAM test object with polymethyl methacrylate plates was imaged on five DBT systems from different vendors. Three DBT acquisitions were performed at mean glandular doses of 1.0 mGy, 2.0 mGy, and 3.5 mGy while maintaining a constant phantom set-up. Eight DBT acquisitions with different test plate positions and phantom set-up thicknesses were performed at clinically applied dose levels. Additionally, three conventional two-dimensional mammogram images were acquired with different phantom thicknesses. Six radiologists ranked the systems based on the visibilities of the targets seen in the phantom images. RESULTS: In the DBT acquisitions performed at comparable dose levels, one system differed significantly from all other systems in microcalcification scores. When using site-specific DBT protocols, significant differences were found between the devices for microcalcification, filament, and low-contrast targets. A strong correlation was observed between the reviewer scores and radiation doses in DBT acquisitions, whereas no such correlation was observed in the 2D acquisitions. CONCLUSION: In DBT acquisitions, dose level was found to be a major factor explaining image quality differences between the systems, regardless of other acquisition parameters. Most DBT systems performed equally well at similar dose levels.


Assuntos
Mamografia , Imagens de Fantasmas , Mamografia/instrumentação , Mamografia/métodos , Mamografia/normas , Radiologistas , Calcinose , Mama/diagnóstico por imagem , Humanos , Feminino
2.
Pan Afr Med J ; 41: 301, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35855027

RESUMO

Introduction: to address the challenge of inadequate and non-equitable distribution of diagnostic imaging equipment, countries are encouraged to evaluate the distribution of installed systems and undertake adequate monitoring to ensure equitability. Ghana´s medical imaging resources have been analyzed in this study and evaluated against the status in other countries. Methods: data on registered medical imaging equipment were retrieved from the database of the Nuclear Regulatory Authority and analyzed. The equipment/population ratio was mapped out graphically for the 16 regions of Ghana. Comparison of the equipment/population ratio was made with the situation in other countries. Results: six hundred and seventy-four diagnostic imaging equipment units from 266 medical imaging facilities (2.5 units/facility), comprising computed tomography (CT), general X-ray, dental X-ray, single-photon emission computed tomography (SPECT) gamma camera, fluoroscopy, mammography and magnetic resonance imaging (MRI) were surveyed nationally. None of the imaging systems measured above the Organization for Economic Co-operation and Development (OECD) average imaging units per million populations (u/mp). The overall equipment/population ratio estimated nationally was 21.4 u/mp. Majority of the imaging systems were general X-ray, installed in the Greater Accra and Ashanti regions. The regional estimates of equipment/population ratios were Greater Accra (49.6 u/mp), Ashanti (22.4 u/mp), Western (21.4 u/mp), Eastern (20.6 u/mp), Bono East (20.0 u/mp), Bono (19.2 u/mp), Volta (17.9 u/mp), Upper West (16.7 u/mp), Oti (12.5 u/mp), Central (11.9 u/mp), Northern (8.9 u/mp), Ahafo (8.9 u/mp), Upper East (6.9 u/mp), Western North (6.7 u/mp), Savannah (5.5 u/mp) and North-East (1.7 u/mp). Conclusion: medical imaging equipment shortfall exist across all imaging modalities in Ghana. A wide inter-regional disparity in the distribution of medical imaging equipment exists contrary to WHO´s recommendation for equitable distribution. A concerted national plan will be needed to address the disparity.


Assuntos
Equipamentos para Diagnóstico , Diagnóstico por Imagem , Equidade em Saúde , Instalações de Saúde , Disparidades em Assistência à Saúde , Equipamentos para Diagnóstico/normas , Equipamentos para Diagnóstico/estatística & dados numéricos , Equipamentos para Diagnóstico/provisão & distribuição , Diagnóstico por Imagem/instrumentação , Diagnóstico por Imagem/estatística & dados numéricos , Fluoroscopia/instrumentação , Gana/epidemiologia , Equidade em Saúde/estatística & dados numéricos , Instalações de Saúde/estatística & dados numéricos , Instalações de Saúde/provisão & distribuição , Disparidades em Assistência à Saúde/estatística & dados numéricos , Humanos , Mamografia/instrumentação , Radiografia/instrumentação
3.
Medicine (Baltimore) ; 100(38): e27243, 2021 Sep 24.
Artigo em Inglês | MEDLINE | ID: mdl-34559124

RESUMO

ABSTRACT: To compare the performance of margin assessment of specimen mammography (SM) in patients with breast-conserving surgery (BCS) on mobile devices and 5-megapixel (5M) thin film transistor liquid crystal display (TFT-LCD) monitors based on the safety margin for pathologic results.This retrospective study was approved by the institutional review board, and the requirement for informed consent was waived. A total of 105 consecutive breast cancer SM samples from 104 women who underwent BCS were included in the study. The SM were independently reviewed by two radiologists using mobile devices and by two additional radiologists using 5M TFT-LCD monitor. Each reader was asked to measure the shortest distance between the lesion and the lesion margin. The interpretation time was recorded. The sensitivity, specificity, and interobserver agreement were analyzed.In total, 19% (20/105) breast specimens had a positive surgical margin (<1 mm). The mean absolute difference from the pathologic margin was 0.60 ±â€Š0.57 cm and 0.54 ±â€Š0.47 cm using the 5 M TFT-LCD monitor and the mobile device, respectively (without any statistical significance, P = .273). The mean interpretation time was 49.5 and 47.6 s for the 5M TFT-LCD monitor and the mobile device, respectively (P = .012). The pooled sensitivity and specificity were 60% and 74% for 5M TFT-LCD monitor, and 60% and 69% for the mobile device (P = 1.00 and P = .190, respectively). The kappa coefficient indicated moderate agreement for both the displays.The diagnostic performance for margin assessment of SM in BCS patients on mobile devices and 5M TFT-LCD monitors are showed not statistically difference. The findings of the study provide evidence of the benefit of the mobile device for SM interpretation in patients who underwent BCS. However, a large sample size study is warranted before using a mobile device for margin evaluation on SM.The mobile device showed comparable diagnostic performance with 5M TFT-LCD monitor in the evaluation of SM margin in patients with BCS and could be used as a display tool for immediate assessment when a dedicated LCD monitor is unavailable.


Assuntos
Telefone Celular/normas , Mamografia/métodos , Margens de Excisão , Mastectomia Segmentar/normas , Área Sob a Curva , Mama/cirurgia , Telefone Celular/instrumentação , Humanos , Imageamento por Ressonância Magnética/métodos , Mamografia/instrumentação , Mastectomia Segmentar/métodos , Mastectomia Segmentar/estatística & dados numéricos , Curva ROC , Estudos Retrospectivos , Seul , Tomografia Computadorizada por Raios X/métodos
4.
Arch Gynecol Obstet ; 304(2): 559-566, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33970324

RESUMO

PURPOSE: The FUSION-X-US-II prototype was developed to combine 3D-automated breast ultrasound (ABUS) and digital breast tomosynthesis in a single device without decompressing the breast. We evaluated the technical function, feasibility of the examination workflow, image quality, breast tissue coverage and patient comfort of the ABUS device of the new prototype. METHODS: In this prospective feasibility study, the FUSION-X-US-II prototype was used to perform ABUS in 30 healthy volunteers without history of breast cancer. The ABUS images of the prototype were interpreted by a physician with specialization in breast diagnostics. Any detected lesions were measured and classified using BI-RADS® scores. Image quality was rated subjectively by the physician and coverage of the breast was measured. Patient comfort was evaluated by a questionnaire after the examination. RESULTS: One hundred and six scans were performed (61 × CC, 23 × ML, 22 × MLO) in 60 breasts. Image acquisition and processing by the prototype was fast and accurate. Breast coverage by ABUS was approximately 90.8%. Sixteen breast lesions (all benign, classified as BIRADS® 2) were identified. The examination was tolerated by all patients. CONCLUSION: The FUSION-X-US-II prototype allows a rapid ABUS scan with mostly high patient comfort. Technical developments resulted in an improvement of quality and coverage compared to previous prototype versions. The results are encouraging for a test of the prototype in a clinical setting in combination with tomosynthesis.


Assuntos
Mama/diagnóstico por imagem , Diagnóstico por Computador/instrumentação , Mamografia/instrumentação , Imagem Multimodal/instrumentação , Ultrassonografia Mamária/instrumentação , Adulto , Neoplasias da Mama/diagnóstico por imagem , Estudos de Viabilidade , Feminino , Voluntários Saudáveis , Humanos , Mamografia/métodos , Pessoa de Meia-Idade , Imagem Multimodal/métodos , Estudo de Prova de Conceito , Estudos Prospectivos , Ultrassonografia Mamária/métodos
5.
PLoS One ; 16(4): e0250005, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33848318

RESUMO

MammoWave is a microwave imaging device for breast lesions detection, which operates using two (azimuthally rotating) antennas without any matching liquid. Images, subsequently obtained by resorting to Huygens Principle, are intensity maps, representing the homogeneity of tissues' dielectric properties. In this paper, we propose to generate, for each breast, a set of conductivity weighted microwave images by using different values of conductivity in the Huygens Principle imaging algorithm. Next, microwave images' parameters, i.e. features, are introduced to quantify the non-homogenous behaviour of the image. We empirically verify on 103 breasts that a selection of these features may allow distinction between breasts with no radiological finding (NF) and breasts with radiological findings (WF), i.e. with lesions which may be benign or malignant. Statistical significance was set at p<0.05. We obtained single features Area Under the receiver operating characteristic Curves (AUCs) spanning from 0.65 to 0.69. In addition, an empirical rule-of-thumb allowing breast assessment is introduced using a binary score S operating on an appropriate combination of features. Performances of such rule-of-thumb are evaluated empirically, obtaining a sensitivity of 74%, which increases to 82% when considering dense breasts only.


Assuntos
Mama/diagnóstico por imagem , Mamografia/métodos , Adulto , Idoso , Algoritmos , Área Sob a Curva , Neoplasias da Mama/diagnóstico , Feminino , Humanos , Mamografia/instrumentação , Imageamento de Micro-Ondas , Pessoa de Meia-Idade , Curva ROC , Sensibilidade e Especificidade , Adulto Jovem
6.
Expert Rev Med Devices ; 18(5): 413-420, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33784927

RESUMO

Introduction: Percutaneous image-guided biopsy is the procedure of choice for diagnosing suspicious abnormalities on breast imaging. Stereotactic, ultrasound, and magnetic resonance imaging are used for image-guided breast biopsies. Stereotactic guidance uses mammography to localize lesions and facilitate placement of a core biopsy needle. The first systems used a vertical-approach needle insertion. The lateral arm device, which is the most recent advancement in stereotactic biopsies and pre-surgical localization allows procedures to be performed using a needle insertion parallel to the compression plate.Areas covered: The lateral arm device was introduced to the market in 2007 and is the first device of its kind. In this article we review the mechanism of this device, the risks and benefits of the device and other the different other modalities utilized to biopsy and localize the breast. We summarize the current literature on this device along with our own experiences utilizing this device.Expert opinion: The lateral arm device has changed the face of stereotactic-guided breast biopsies and localizations by allowing a new approach to perform these procedures. It has improved care to patients by allowing us to get to areas previously not within the biopsy window, decreased biopsy time and increased patient throughput.


Assuntos
Mama/diagnóstico por imagem , Mamografia/efeitos adversos , Mamografia/instrumentação , Mama/patologia , Mama/cirurgia , Feminino , Humanos , Biópsia Guiada por Imagem , Vigilância de Produtos Comercializados , Controle Social Formal
7.
Sci Rep ; 11(1): 129, 2021 01 08.
Artigo em Inglês | MEDLINE | ID: mdl-33420200

RESUMO

This study aims to evaluate the diagnostic accuracy of digital breast tomosynthesis-guided vacuum assisted breast biopsy (DBT-VABB) of screening detected suspicious mammographic abnormalities comprising of calcifications, asymmetric densities, architectural distortions and spiculated masses. In this institutionally approved study, a total of 170 (n = 170) DBT-VABB were performed, 153 (90%) were for calcifications, 8 (4.7%) for spiculated mass, 5 (2.9%) for asymmetric density and 4 (2.4%) for architectural distortion. All these lesions were not detected on the corresponding ultrasound. Histopathology results revealed 140 (82.4%) benign, 9 (5.3%) borderline and 21 (12.4%) malignant lesions. The total upgrade rate at surgery was 40% for atypical ductal hyperplasia and 5.9% for ductal carcinoma in-situ. 3.6% discordant benign lesions showed no upgrade. DBT-VABB showed 100% specificity, 91.3% sensitivity and 100% positive predictive value (PPV) for detecting malignant lesions. The negative predictive value (NPV) was 80%. 2 (1.2%) patients had mild complications and 1 (0.6%) had severe pain. Our study showed that DBT-VABB was a safe and reliable method, with high sensitivity, specificity, PPV and NPV in the diagnosis of non-palpable benign and malignant breast lesions. Our data also confirmed the accuracy of DBT-VABB in detecting malignant lesions and we suggest further surgical excision in borderline lesions for a more accurate diagnostic evaluation.


Assuntos
Biópsia/métodos , Mama/diagnóstico por imagem , Detecção Precoce de Câncer/métodos , Mamografia/métodos , Adulto , Idoso , Biópsia/instrumentação , Mama/patologia , Mama/cirurgia , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Neoplasias da Mama/cirurgia , Calcinose/diagnóstico por imagem , Calcinose/patologia , Calcinose/cirurgia , Estudos Transversais , Detecção Precoce de Câncer/instrumentação , Feminino , Humanos , Mamografia/instrumentação , Pessoa de Meia-Idade , Estudos Retrospectivos , Ultrassonografia/métodos
8.
Acta Radiol ; 62(12): 1583-1591, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33280392

RESUMO

BACKGROUND: Breast compression in mammography is important but is a source of discomfort and has been linked to screening non-attendance. Reducing compression has little effect on breast thickness, and likely little effect on image quality, due to force being absorbed in the stiff juxta thoracic area instead of in the central breast. PURPOSE: To investigate whether a flexible compression plate can redistribute force to the central breast and whether this affects perceived pain. MATERIAL AND METHODS: Twenty-eight women recalled from mammography screening were compressed with flexible and rigid plates while retaining force and positioning, 15 in the craniocaudal (CC) view and 13 in the mediolateral oblique (MLO) view. Pressure distribution was continuously measured using pressure sensors. RESULTS: The flexible plate showed greater mean breast pressure in both views: 2.8 versus 2.3 kPa for CC (confidence interval [CI] = 0.2-0.8) and 1.0 versus 0.5 kPa for MLO (CI = 0.2-0.6). The percentage of applied force distributed to the breast was significantly higher with the flexible plate, both on CC (36% vs. 22%, CI = 1-11) and MLO (30% vs. 14%, CI = 4-13). CONCLUSION: The flexible plate redistributes pressure to the central breast, achieving a better compression, particularly in the MLO view, though much applied force is still applied to the juxta thoracic region.


Assuntos
Mama/diagnóstico por imagem , Mamografia/instrumentação , Percepção da Dor , Dor Processual/fisiopatologia , Pressão , Adulto , Idoso , Mama/anatomia & histologia , Intervalos de Confiança , Constrição , Feminino , Humanos , Mamografia/efeitos adversos , Mamografia/métodos , Manometria/instrumentação , Pessoa de Meia-Idade , Tamanho do Órgão , Estudos Prospectivos
9.
Cir. plást. ibero-latinoam ; 46(4): 381-400, oct.-dic. 2020. ilus, tab, graf
Artigo em Espanhol | IBECS | ID: ibc-198720

RESUMO

INTRODUCCIÓN Y OBJETIVO: La mastopexia combinada con implantes que presentamos bajo la denominación Técnica reglada, tiene como finalidad el tratamiento en forma simultánea del volumen y posición de la mama usando implantes de gel de silicona, logrando así el aumento y levantamiento de la mama en un solo tiempo quirúrgico, mediante una sistematización en pasos. MATERIAL Y MÉTODO: Describimos esta sistematización basada en 5 reglas fundamentales y presentamos un estudio sobre pacientes que consultaron por hipotrofia, tejido mamario inconsistente y ptosis mamaria con o sin pérdida masiva de peso, en la Unidad de Cirugía Plástica y Posbariátrica de Caracas, Venezuela, entre 2009 y 2019. RESULTADOS: Practicamos mastopexia por Técnica reglada en 481 pacientes entre 19 y 61 años de edad, en las que el 37.63% (n=181) presentaban condición postbariátrica, 23.91% (n=115) fueron cirugías primarias y 56.13% (n=270) cirugías secundarias. En el 84.62% (n=407) realizamos mastopexia con técnica de pedículo superior, que fue la más frecuentemente utilizada en pacientes sin condición postbariátrica (54%); la mastopexia con técnica de pedículo inferior fue la menos utilizada, en el 2.49% (n=12), y mayormente en pacientes con condición postbariátrica (83.33%). En cuanto al patrón de piel, realizamos cicatrices mínimas en el 84% (n=404) y T invertida en el 16% (n=77). Empleamos implantes de silicona redondos con un rango de volumen de 400 a 500 cc en el 62.37% (n=300). Las complicaciones se dieron en el 14.34% (n=69), siendo las más frecuentes: licuefacción grasa (3.95 %), celulitis (3.53%) y seroma (3.11%), con cirugía de revisión en 3 casos. CONCLUSIONES: El paso a paso de la Técnica reglada ofrece al cirujano una guía práctica para realizar en forma efectiva la combinación de mastopexia con el uso de implantes mamarios, con bajo índice de complicaciones demostrado a través de nuestra casuística


BACKGROUND AND OBJECTIVE: Mastopexy combined with implants that we present with the denomination Regulated technique, aims to simultaneously treat the volume and position of the breast, using silicone gel implants, thus achieving the increase and lifting of the breast in a single surgical time, through a systematization of steps. METHODS: We describe this systematization based on 5 main rules, and present an study in patients who consulted for hypotrophy, inconsistent breast tissue and breast ptosis with or without massive weight loss, carried out in patients who attended the Plastic and Postbariatric Surgery Unit (Caracas, Venezuela) during the period 2009-2019. RESULTS: Mastopexy was performed by Regulated technique in 481 patients between 19 and 61 years old; 37.63% (n=181) had postbariatric condition, 23.91% (n=115) were primary surgeries, 56.13% (n=270) secondary surgeries; 84.62% (n=407) underwent mastopexy with the superior pedicle technique, being the most frequently used in patients without post-bariatric condition (54%), and mastopexy with the inferior pedicle technique was the least used, only in (2.49%) (n=12), and mostly in patients with post-bariatric condition (83.33%). Regarding the skin pattern, minimal scars were made in 84% (n=404) and inverted T in 16% (n=77). Round silicone implants with a volume range of 400 to 500 cc were used in 62.37% (n=300). Complications occurred with an incidence of 14.34% (n=69), the most frequent being: fat liquefaction (3.95%), cellulite (3.53%) and seroma (3.11%), only requiring revision surgery in 3 cases. CONCLUSIONS: The step by step of the Regulated technique offers the surgeon a practical guide to effectively perform the combination of mastopexy with the use of breast implants, with a low rate of complications demonstrated by our clinical series


Assuntos
Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Implantes de Mama/normas , Implante Mamário/métodos , Mamoplastia/métodos , Técnicas de Sutura , Pesos e Medidas Corporais/normas , Pesos e Medidas Corporais/instrumentação , Estudos Prospectivos , Índice de Massa Corporal , Complicações Pós-Operatórias , Mamografia/instrumentação , Mamografia/normas
10.
Phys Med Biol ; 65(23): 235033, 2020 12 18.
Artigo em Inglês | MEDLINE | ID: mdl-33080575

RESUMO

The design and testing of a prototype Multi-X-ray-source Array (MXA) for digital breast tomosynthesis is reported. The MXA is comprised of an array of tungsten filament cathodes with focus cup grid-controlled modulation and a common rotating anode housed in a single vacuum envelope. Prototypes consisting of arrays of three-source elements and eleven-source-elements were fabricated and evaluated. The prototype sources demonstrated focal spot sizes of 0.3 mm at 45 kV with 50 mA. Measured x-ray spectra were consistent with the molybdenum anode employed, and the tube output (air kerma) was between 0.6 mGy/100 mAs at 20 kV and 17 mGy/100 mAs at 45 kV with a distance of 100 cm. HVL measurements ranged from 0.5 mm Al at 30 kV to 0.8 mm Al at 45 kV, and x-ray pulse widths were varied from 20 ms to 110 ms at operating frequencies ultimately to be limited by source turn-on/off times of ∼1 ms. Initial results of reconstructed tomographic data are presented.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mamografia/instrumentação , Mamografia/métodos , Imagens de Fantasmas , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/métodos , Feminino , Humanos
12.
J Xray Sci Technol ; 28(6): 1157-1169, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32925159

RESUMO

Breast cancer is the most frequently diagnosed cancer in women worldwide. Digital breast tomosynthesis (DBT), which is based on limited-angle tomography, was developed to solve tissue overlapping problems associated with traditional breast mammography. However, due to the problems associated with tube movement during the process of data acquisition, stationary DBT (s-DBT) was developed to allow the X-ray source array to stay stationary during the DBT scanning process. In this work, we evaluate four widely used and investigated DBT image reconstruction algorithms, including the commercial Feldkamp-Davis-Kress algorithm (FBP), the simultaneous iterative reconstruction technique (SIRT), the simultaneous algebraic reconstruction technique (SART) and the total variation regularized SART (SART-TV) for an s-DBT imaging system that we set up in our own laboratory for studies using a semi-elliptical digital phantom and a rubber breast phantom to determine the most superior algorithm for s-DBT image reconstruction among the four algorithms. Several quantitative indexes for image quality assessment, including the peak signal-noise ratio (PSNR), the root mean square error (RMSE) and the structural similarity (SSIM), are used to determine the best algorithm for the imaging system that we set up. Image resolutions are measured via the calculation of the contrast-to-noise ratio (CNR) and artefact spread function (ASF). The experimental results show that the SART-TV algorithm gives reconstructed images with the highest PSNR and SSIM values and the lowest RMSE values in terms of image accuracy and similarity, along with the highest CNR values calculated for the selected features and the best ASF curves in terms of image resolution in the horizontal and vertical directions. Thus, the SART-TV algorithm is proven to be the best algorithm for use in s-DBT image reconstruction for the specific imaging task in our study.


Assuntos
Mama/diagnóstico por imagem , Mamografia , Nanotubos de Carbono/química , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X , Algoritmos , Feminino , Humanos , Mamografia/instrumentação , Mamografia/métodos , Imagens de Fantasmas , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/métodos
13.
Sci Rep ; 10(1): 14087, 2020 08 24.
Artigo em Inglês | MEDLINE | ID: mdl-32839488

RESUMO

Breast shapes are affected by gravitational loads and deformities. Measurements obtained in the standing position may not correlate well with measurements in the supine position, which is more representative of patient position during breast surgery. A dual color 3D surface imaging system capable of scanning patients in both supine and standing positions was developed to evaluate the effect of changes in body posture on breast morphology. The system was evaluated with  breast phantoms to assess accuracy, then tested on ten subjects in three body postures to assess its effectiveness as a clinical tool. The accuracy of the system was within 0.4 mm on average across the model. For the human study, there was no effect of body posture on breast volumes (p value > 0.05), but we observed an effect of completeness of breast scans on body posture (p value < 0.05). Post-hoc tests showed that the supine position and the standing position with hands at the waist differed significantly (p value < 0.05). This study shows that the system can quantitatively evaluate the effect of subject postures, and thereby has the potential to be used to investigate peri-operative changes in breast morphology.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mama/diagnóstico por imagem , Imageamento Tridimensional/métodos , Mamografia/instrumentação , Imagens de Fantasmas , Mama/anatomia & histologia , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Mamografia/métodos , Tamanho do Órgão/fisiologia , Posição Ortostática , Decúbito Dorsal , Pesquisa Translacional Biomédica
14.
Phys Med Biol ; 65(24): 245003, 2020 12 05.
Artigo em Inglês | MEDLINE | ID: mdl-32693400

RESUMO

A standard protocol for performance evaluation of positron emission mammography (PEM) systems has not yet been established. In this work we propose a methodology based on the design of specific phantoms for this imaging modality with component dimensions in accordance with typical breast lesion sizes together with the adaptation of current international protocols designed for clinical and preclinical positron emission tomographs (PET) systems. This methodology was used to evaluate the performance of the Flex Solo II PEM scanner in terms of spatial resolution, uniformity and contrast lesion detectability, recovery coefficients and spill-over ratios. Positron range effects were studied with 18F and 68Ga, which have very different energy spectra. Our results indicate that in-plane spatial resolution of the system is around 3.0 mm and 4.4 mm for 18F and 68Ga, respectively. Lesion detectability tests with sphere diameters between 4 and 10 mm confirmed that the PEM system can resolve all the spheres (hot or cold). Percent contrast values for 18F lie between 6%-38% and 34%-51% for hot- and cold- spheres, respectively; the corresponding intervals for 68Ga are lower, 4%-25% and 32%-44%. Regarding uniformity quantification, the system shows percentage standard deviations within 4.9%-5.7%, while the percent background variability measurements ranged between 6.7% and 10.9% for both radionuclides. Recovery coefficients measured with hot rod diameters between 1.5 and 9 mm, have values between 0.2-1.05 and 0.17-0.69 for 18F and 68Ga, respectively. Spill-over ratios have large values (0.22 in average) for both radionuclides. Our results indicate that the phantoms and the methodology developed in this work can serve as the basis for establishing an image quality protocol for the systematic evaluation of PEM systems, with a potential extension for performance evaluation of dedicated breastPET scanners.


Assuntos
Elétrons , Mamografia/instrumentação , Imagens de Fantasmas , Desenho de Equipamento , Controle de Qualidade , Tomografia Computadorizada de Emissão
15.
Anticancer Res ; 40(7): 3915-3924, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32620632

RESUMO

BACKGROUND: Wire-guided localization (WGL) has been the mainstay for localizing non-palpable breast lesions before excision. Due to its limitations, various wireless alternatives have been developed. In this prospective study, we evaluate the role of radiation-free wireless localization using the SAVI SCOUT® localization at a European centre. PATIENTS AND METHODS: This technique was evaluated in a prospective cohort of 20 patients. The evaluation focused on clinical and pathological parameters in addition to patient and physician acceptance. RESULTS: SAVI SCOUT reflectors (n=23) were deployed to localize 22 occult breast lesions and one axillary lymph node in 20 patients. The mean deployment duration was 5.6 min, with a mean distance from the lesion of 0.6 mm. The migration rate was 0% and the mean identification and retrieval time was 25.1 min. In patients undergoing therapeutic excision for malignancy (n=17), only one (5.9%) required reoperation for positive surgical margins. Radiologists and surgeons rated the technique as better than WGL and patient satisfaction was high. CONCLUSION: Our study demonstrates that wireless localization using SAVI SCOUT® is an effective and time-efficient alternative to WGL with excellent physician and patient acceptance.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Diagnóstico por Imagem/métodos , Adulto , Idoso , Neoplasias da Mama/cirurgia , Diagnóstico por Imagem/instrumentação , Feminino , Humanos , Raios Infravermelhos , Mamografia/instrumentação , Mamografia/métodos , Pessoa de Meia-Idade , Radar
16.
Arch Gynecol Obstet ; 301(5): 1257-1265, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32215718

RESUMO

PURPOSE: To compare automated breast volumetric scanning (ABVS) with hand-held bilateral whole breast ultrasound (HHUS) prospectively in regards to patient workflow, woman preference, efficacy in lesion detection, and characterization. MATERIALS AND METHODS: Supplemental screening was performed with both ABVS and HHUS to 345 women with dense breasts and negative mammograms. Acquisition and evaluation times were recorded. Lesions were classified according to BIRADS US criteria and compared one to one. Women were recalled for a secondary HHUS examination if ABVS showed any additional lesions. Findings were compared based on biopsy results and/or 36-48 months of follow-up. RESULTS: Findings could be compared for 340 women. There were two carcinomas which were detected by both methods, with no interval cancers in the follow-up period. Recall rate was 46/340 (13.05%) for ABVS and 4/340 (1.18%) for HHUS. ABVS recalls decreased with experience. HHUS had more true negative (BIRADS 1-2) results, while ABVS had more false positive ones (p < 0.001). Positive predictive value was 4.17% for ABVS and 50% for HHUS. ABVS overdiagnosed shadowings (p < 0.01), distortions (p < 0.034), and irregular nodules (p < 0.001) in comparison to HHUS. At ABVS, 10.6% of women experienced severe pain. 59.7% stated that they would choose HHUS if they had the chance. CONCLUSION: ABVS is as good as HHUS in lesion detection. However, the recall rate is higher and positive predictive value is lower with ABVS, which could result in more follow-ups, and more anxiety for the women. More than 50% women stated they would prefer HHUS if they were given the chance.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mama/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Mamografia/métodos , Reconhecimento Automatizado de Padrão/métodos , Ultrassonografia Mamária/métodos , Adulto , Idoso , Biópsia , Mama/patologia , Densidade da Mama , Neoplasias da Mama/patologia , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Mamografia/instrumentação , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Sensibilidade e Especificidade , Ultrassonografia Mamária/instrumentação
17.
ISA Trans ; 103: 156-165, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32216985

RESUMO

Since uncontrolled growth of malignant masses introduces uneven shape irregularities and spiculations in the boundary, shape representing shift invariant features are essential to resolve the problem of discrimination. However, ambiguous nature of shape, size, margin, orientation of masses produces imprecise feature values. In this view, a new concept of extrema based feature characterization scheme is proposed for capturing radiating nature of mass morphology. Computation of extrema patterns needs only few algorithmic steps. Beside this, present study employs an automated enhancement procedure to improve the classification accuracy. Experimental results show that extrema characterization reduces the feature redundancy to produce high efficiency in reasonably low time.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mamografia/instrumentação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Algoritmos , Bases de Dados Factuais , Feminino , Humanos , Mamografia/métodos , Reprodutibilidade dos Testes
18.
Phys Med ; 71: 137-149, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32143121

RESUMO

A tracking and reporting system was developed to monitor radiation dose in X-ray breast imaging. We used our tracking system to characterize and compare the mammographic practices of five breast imaging centers located in the United States and Brazil. Clinical data were acquired using eight mammography systems comprising three modalities: computed radiography (CR), full-field digital mammography (FFDM), and digital breast tomosynthesis (DBT). Our database consists of metadata extracted from 334,234 images. We analyzed distributions and correlations of compressed breast thickness (CBT), compression force, target-filter combinations, X-ray tube voltage, and average glandular dose (AGD). AGD reference curves were calculated based on AGD distributions as a function of CBT. These curves represent an AGD reference for a particular population and system. Differences in AGD and imaging settings were attributed to a combination of factors, such as improvements in technology, imaging protocol, and patient demographics. The tracking system allows the comparison of various imaging settings used in screening mammography, as well as the tracking of patient- and population-specific breast data collected from different populations.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Mamografia/instrumentação , Mamografia/métodos , Algoritmos , Brasil , Mama/diagnóstico por imagem , Força Compressiva , Detecção Precoce de Câncer , Feminino , Humanos , Imagens de Fantasmas , Garantia da Qualidade dos Cuidados de Saúde , Doses de Radiação , Intensificação de Imagem Radiográfica/métodos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Estados Unidos
19.
J Nucl Med Technol ; 48(2): 181-183, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32111663

RESUMO

Textitis is a new term used to refer to the degenerative-strain osteoarthritis that comes from excessive use of a smart phone. 18F-NaF is increasingly used in diagnosing skeletal pain that is not identified on radiographs. We report a case of a 26-y-old woman with left breast cancer referred for 18F-NaF PET/CT, who was complaining of right thumb and wrist pain. Findings were negative for bone secondaries. Dedicated hands views were acquired on a positron emission mammography scanner and showed focal uptake at the first carpometacarpal and second metacarpophalangeal joints. On the basis of the strong history, the findings were likely due to active arthritic changes caused by repetitive strain injury from excessive text messaging.


Assuntos
Radioisótopos de Flúor , Mamografia/instrumentação , Osteoartrite/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/instrumentação , Razão Sinal-Ruído , Fluoreto de Sódio , Envio de Mensagens de Texto , Adulto , Feminino , Humanos , Osteoartrite/etiologia
20.
J Synchrotron Radiat ; 27(Pt 2): 503-506, 2020 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-32153291

RESUMO

The vertical intensity distribution of synchrotron-based X-ray beams usually has a Gaussian profile encompassing large intensity variations. For biomedical imaging applications this may entail sub-optimal dose distributions and large fluctuations in terms of image noise. Commonly, planar metallic filters coupled with absorbing slits systems are applied to adjust the delivered flux and to limit intensity variations, respectively. The latter results in a reduction of the effective beam size. A flattening filter that counterbalances the transverse inhomogeneity, while retaining a sufficient flux, has been developed in the context of a monochromatic phase-contrast breast computed tomography application, ongoing at the Elettra synchrotron facility. The implementation of the new filtration system results in homogeneous intensity (hence dose) distribution and signal-to-noise ratio across the imaged volume. Finally, and most importantly, it allows a wider portion of the beam to be used, directly translating into a major (∼40%) reduction of the overall scan time for samples requiring a field of view larger than the beam size (i.e. multiple translation steps).


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Tomografia Computadorizada por Raios X/instrumentação , Simulação por Computador , Desenho de Equipamento , Feminino , Humanos , Mamografia/instrumentação , Doses de Radiação , Razão Sinal-Ruído , Síncrotrons